TB0339A Page 8 of 9 10/18/03
SERVICE
This unit is designed to provide years of reliable service under even the worst conditions. Many times there may
appear to be a problem with the unit when the true problem is in the speaker(s), controlled devices, or improper
installation. The following chart shows typical symptoms and possible causes.
A blown siren fuse doesn't necessarily mean that the unit is bad. If a speaker or speaker lead is shorted this fuse will
blow before the unit is damaged. Disconnect the SPKR leads and replace the fuse. If the unit itself emits a low level
sound when in the Yelp position it is OK. Check the speaker(s) or leads for possible shorting.
Note: Original shipments of this unit used 20AMP fuses to protect the light control outputs. 25AMP fuses are now
recommended to prevent overheating of the output connection block. The outputs should still be limited to 20AMPS.
PROBLEMS
Symptom Possible Cause Check
No Power or siren output Power switch not turned on
Bad Speaker
Connector or connections loose
Siren fuse blown
Loose connection at power source
Does backlighting come on?
Do you hear a “pop” when turned on?
With siren on, yelp selected, listen for tone in amplifier.
Is an external fuse or circuit breaker used?
Are the power leads connected to a good buss?
No siren tone
PA works
High Voltage Protection
PA PTT button stuck
The input voltage must be less than highest rating.
Does PTT button release properly?
No PA PA volume not set properly Try turning the PA volume control.
Distorted siren sound Speaker assembly loose
Intermittent Aux Input connection
Low vehicle voltage
Is the speaker bell or tip loose?
Is the Aux Siren Input used and wired properly?
The input voltage must be greater than lowest rating.
Intermittent siren tone High Voltage Protection
Connector or connections loose
Loose connection at power source
PA PTT button activation
Circuit breaker in supply
connection
Is the vehicle voltage regulator working properly?
Is the connector tight on the back of the unit?
Check for loose leads back to power source.
Is something lying on PTT button?
Is a circuit breaker used with at least 50A rating?
Horn or Manual or
Two-Tone stuck on
Siren button switch stuck
Aux Siren switch stuck
Aux Input improperly connected
Does the Siren button switch return fully when released?
Does the Aux Siren switch return fully when released?
Is the Aux Siren Input used and wired properly?
No Radio Unit not connected to a radio
Radio volume too low
Is the radio connected properly to the unit?
Can you hear the radio in the vehicle?
Try setting the Radio Volume Adjust.
Wrong siren tone Automatic Siren Override Move slide switch off of position 3?
Automatic Siren not
working
Automatic Siren disabled Is the Automatic Siren option off?
Light Output not working Light Control Output fuse blown
Internal relay contacts bad
Is the light or device shorting?
Is the output current limited to 20AMPS?
Light Output stays on Internal relay contacts fused from
overheating
Is the output current exceeding 20AMPS?
RETURN
If you have any questions concerning this or any other Carson product, please contact our Technical Service
Department at (888) 577-6877. Many issues can be handled over the phone. We can also be reached via e-mail at
If a product must be returned for any reason, please contact our Technical Service Department to obtain a Returned
Merchandise Authorization number (RMA#) before you ship the product to Carson. Please write the RMA# clearly on
the package near the mailing label. Be sure to provide a return address, contact and phone number, along with a brief
description of the problem.